Well pressure tank problems: warning signs for Chester County homeowners

If your home around West Chester runs on a private well, a failing pressure tank can wear out the pump. Here are the signs to watch for and what to do about them.

Key takeaway: A pump that clicks on and off every few seconds, sputtering faucets or water coming out of the tank’s air valve all point to a pressure tank problem. Fixing it early protects the well pump.

Plumber adjusting a valve on a home water supply pipe in West Chester, PA

If your home is on a private well, your water system has three main parts: the well pump, a pressure switch and a pressure tank. The tank stores water under pressure so the pump does not have to start every time you open a faucet.

When the tank stops doing its job, the pump starts and stops far more often than it should. Over time, that wears out the pump.

Warning signs of a failing pressure tank

A guide from Fresh Water Systems lists these symptoms:

  • Short cycling: the pump clicks on and off every few seconds.
  • Water coming out of the air valve on top of the tank, which signals a ruptured bladder that requires tank replacement.
  • A solid thud when you knock on the tank, which suggests it is waterlogged.
  • Faucets spitting or sputtering air, which can mean the bladder has failed.
  • Pressure that rises and falls in showers and faucets.
  • A tank that keeps losing its air charge.
  • Rust, drips or puddles around the tank, which mean the tank needs replacing.

Why short cycling matters

The same guide explains that a ruptured bladder makes the pressure switch flip rapidly between on and off. That overheats the pump and can cause it to fail. An undersized tank can cause the same problem.

InterNACHI’s life expectancy chart lists about 15 years for a well pump under normal conditions. Constant short cycling puts extra wear on it.

The air charge rule

Most bladder tanks rely on a cushion of air set to the right pressure. Fresh Water Systems says an empty tank should be set to 2 psi below the pump’s cut-on pressure. For a common 30/50 pressure switch, that is 28 psi. If the charge is wrong, the tank cannot hold enough water and the pump cycles too often.

Checking and setting the air charge means shutting off power to the pump and draining the tank. If you are not comfortable working near the pressure switch, which carries line voltage, leave it to a plumber.

Who regulates wells in Chester County

The Chester County Health Department handles well permitting and provides forms and procedures for well installation, maintenance and disinfection. It is located at 601 Westtown Road in West Chester and can be reached at 610-344-6225.

Pressure tank work does not replace water testing. The Pennsylvania DEP recommends testing private well water every year for total coliform bacteria, nitrates, total dissolved solids and pH. Our guide to private well water testing in Chester County explains what to test and when.

When to call a plumber

Call if your pump short cycles, if water comes out of the tank’s air valve, or if you lose water pressure entirely. A plumber can test the tank, set the air charge correctly, check the pressure switch and replace the tank if the bladder has failed, before the pump burns out.

Harry, author at West Chester PA Plumber
Written by

Harry

Harry writes and reviews the homeowner guides on West Chester PA Plumber. He holds an MBA from Harvard University and focuses on explaining plumbing problems, costs and next steps in plain language, so West Chester homeowners know what to ask before they hire a contractor.

More about Harry
Pump clicking on and off?Call for well pressure tank and pump service around West Chester. You get a written price before any work begins.
Call (610) 788-0057

Well pressure tank questions

Why does my well pump keep turning on and off?

Rapid on-and-off cycling is called short cycling. It is often caused by a ruptured bladder or waterlogged pressure tank, or a tank that is too small. It can overheat and damage the pump.

What should my well pressure tank air charge be?

A common rule is 2 psi below the pump’s cut-on pressure, measured with the tank empty. For a 30/50 pressure switch, that is 28 psi.

How often should I test my well water in Chester County?

The Pennsylvania DEP recommends testing every year for total coliform bacteria, nitrates, total dissolved solids and pH. For help, call (610) 788-0057.